Anyone who has slept in a converted container knows the morning:
the duvet against the outer wall is damp, there are fine beads of water in the
corner, rust spots on the steel. The trade calls it container rain. The cause
is not mysterious. At 20 °C and 60 percent relative humidity the dew point is
about 12 °C; the moment the inner steel surface drops below that, moisture in
the air condenses onto it. Steel has very little thermal mass, so two or three
hours after sunset the surface is already under the dew point, and it stays
there all night.
Water itself draws
no power; dealing with it does. Put a 300 W dehumidifier in the cabin, run it
continuously, and it uses 7.2 kWh a day. A small cabin's total daily
consumption is usually 3–6 kWh, so dehumidification can take more than half —
more than lighting, television and phone charging combined. Worse, the load is
invisible: it never appears on the appliance list, it gets omitted from the
load calculation, and the shortfall only shows up on site.
The order cannot be
reversed. Keep vapour out of the insulation first: the vapour barrier goes on
the warm side, every seam, back box and penetration is sealed, and no
convective cavity is left inside the wall. Then add active drying, and size it
for the wet season rather than the annual average. Get the barrier right and
the dehumidifier drops from continuous running to occasional starts — a five-
to eight-fold difference in energy for the same machine.